Lietuviškai | English

PRODUKTAI


Pasirinkite veiklos sritį, po to produktą dešinėje.


AVIGA   |   EUROTERA   |   GERAGRA   |   MEDICININĖ TECHNIKA


Nuotrauka Pavadinimas Techn. charakteristikos Kaina
be PVM
Paveiksliukas nerastas
CALO-11, 11A, 13, 15 Bomb Calorimeters - Kalorimetrai
Daugiau

CALO-11, CALO-11A, CALO-13, CALO-15, Calorimeters

Applications

The CALO Series calorimeters can be used to determine the calorific value of coal, coke, petroleum, cement black meal, solid biomass fuels and other combustibles. Conformance with Standards: GB/T213-2008 Standard Test Method for Calorific Value of Coal ASTM D5865-2010 Standard Test Method for Gross Calorific Value of Coal and Coke ISO1928 Solid Mineral Fuels – Determination of gross calorific value by the bomb calorimetric method and calculation of net calorific value.

High Adaptability to Environment

Stable internal environment

Jacket and jacket lid equipped with water circulation device and temperature control system, which can make sure the

water temperature of each part of the jacket to be consensus and constant, thus the test results will not be affected even if the room temperature fluctuates up to 10°C.

High Precision and Accuracy of Test Results

Independent bucket and jacket water system

Bucket water will be drained to water tank directly after finishing the test, so the inlet and outlet of bucket water will not affect the jacket water.

Constant bucket water volume and temperature

Constant volumetric tank with temperature control device makes sure water volume and temperature of each test are exactly the same.

High temperature resolution

Temperature measured by PT1000 Platinum resistance to the nearest 0.0001k.

Stable and reliable water quality

Equipped with high quality water purification device, the water quality of each test is guaranteed.

MODEL

CALO-11 Bomb Calorimeter vertikalus

 

CALO-11A Bomb Calorimeter stalinis

CALO-13 Bomb Calorimeter stalinis

 

CALO-15 Bomb Calorimeter vertikalus

Method

Isoperibol

Isoperibol

Isoperibol

Isoperibol

Analysis time

< 11 min.

< 11 min.

<13 min.

< 15 min.

Precision

RSD < 0,1 %

RSD < 0,1 %

RSD < 0,1 %

RSD < 0,1 %

Heat Capacity Stability

0,20 % within three months

0,20 % within three months

0,20 % within three months

0,20 % within three months

Heat Capacity Precision

0,1 %

0,1 %

0,1 %

0,1 %

Temperature Resolution

0,0001K

0,0001K

0,0001K

0,0001K

Power Requirement

220 V, 50 Hz

220 V, 50 Hz

220 V, 50 Hz

220 V, 50 Hz

Max. Power

1,5 kW

1,5 kW

1,5 kW

1,5 kW

Gas Requirement

O2 99,5 % purity

O2 99,5 % purity

O2 99,5 % purity

O2 99,5 % purity

Water Requirement

Distilled water

Distilled water

Distilled water

Distilled water

Standard Layout

Calorimeter, PC, Printer, Water Tank

Calorimeter, PC, Printer

Calorimeter, PC, Printer, Water Tank

Calorimeter, PC, Printer, Water Tank

Type

Benchtop

Vertical

Benchtop

Benchtop

Size

432 x 560 x 393 mm

437 x 554 x 1040 mm

432 x 560 x 393 mm

432 x 560 x 393 mm

Weight

60 kg

95 kg

60 kg

60 kg

Mažiau
0,00LT
CALO-B Bomb Calorimeter – Kalorimetras stalinis
Daugiau

CALO-B Bomb Calorimeter – Kalorimetras stalinis

Features

Weighing the weight and measuring the water temperature of bucket manually, then the calorimeter will finish the whole test automatically.

Simple structure, easy for maintenance.

Durable bombs need hydrostatic pressure test only once a year.

With PCI interface, several calorimeters can be controlled by a single PC.

Connect with balance and network by standard interface RS232, real time data can be transmitted through Internal network.

Easy-to-use Windows-based software, easy data handling.

Analysis Time < 25 min

Heat Capacity Stability 0.20% within three months

Heat Capacity Precision 0.2%

Temperature Resolution 0.0001K

Power Requirement 220V(-15%-10%), 50Hz

Max Power 0.5kW

Gas Requirement 99.5% purity of oxygen

Water Requirement Distilled water

Size / Net weight 528x330x380mm / 30Kg

Mažiau
0,00LT
CALO-40 Bomb Calorimeter – Kalorimetras vertikalus
Daugiau

CALO-40 Bomb Calorimeter – Kalorimetras vertikalus

Features

Vertical type, jacket water 40kgs which can ensure the stability of jacket water temperature.

Test finished automatically

- Automatic oxygen filler equipped, oxygen filling by one press.

- Automatic sample ignition.

- Automatic temperature rise measurement and result calculation.

High temperature resolution, temperature measured by PT1000 Platinum resistance to the nearest 0.0001k to improve the test precision.

Durable bombs need hydrostatic pressure test only once a year.

With PCI interface, several calorimeters can be controlled by a single PC.

Connected with balance and network by standard interface RS232, real time data can be transmitted through internal network.

Easy-to use Windows-based software, easy data handling.

Analysis Time 15~25 min

Heat Capacity Stability 0.20% within three months

Heat Capacity Precision 0.15%

Temperature Resolution 0.0001K

Power Requirement 220V(-15%~10%), 50Hz

Max Power 0.5kW

Gas Requirement 99.5% purity of oxygen

Water Requirement Distilled water

Size / Net weight 600x417x908mm / 89Kg

Mažiau
0,00LT